EEJ Electric Fire Fighting System is a complete fire pump package consisting of two electric fire pumps (duty and standby) and one jockey pump, providing reliable pressure maintenance and emergency water supply for fire protection systems.
The CHINHER EEJ Electric Fire Fighting System is a complete fire pump package consisting of two electric fire pumps (duty and standby) and one jockey pump, providing reliable pressure maintenance and emergency water supply for fire protection systems.
The jockey pump automatically maintains system pressure during standby operation, while the duty electric fire pump starts automatically when pressure drops due to fire demand. The standby electric fire pump serves as a backup to ensure uninterrupted system operation and maximum reliability.
Designed for commercial, industrial, and municipal fire protection applications, the EEJ system is factory-assembled with pumps, control panels, valves, piping, and a common base frame, reducing installation time and simplifying on-site commissioning.
CHINHER offers customized configurations, pump capacities, control systems, voltages, frequencies, and OEM & ODM manufacturing services to meet different international project requirements.
| Medium | Clean water |
| Flow | 50 to 2500 GPM |
| Head | 6 to 14 Bar |
| Speed | 2900 L/min(50hz) 3500L/min(60hz) |
| Diesel | Engine-matched per model |
| Control Mode | Fully automatic (manual & remote options available) System Configuration |
Electric Main Pump: Single-stage end suction or multistage centrifugal pump driven by a high-efficiency TEFC motor.
Jockey Pump: Low-flow, high-pressure jockey pump to maintain constant pipeline pressure and prevent unnecessary main pump starts.

-Secure Packing: Shipped in heavy-duty, sea-freight-approved plywood cases (fumigation-free).
-Quality Guaranteed: 100% factory inspection and dynamic pressure testing prior to shipment.
Get professional support from our engineering team.
✓ Custom Design
✓ Fast Quotation
✓ OEM Available
✓ Global Shipping
CHINHER specializes in manufacturing complete fire pump systems for commercial and industrial fire protection applications worldwide.
We provide:
EEJ refers to a fire pump system consisting of two electric fire pumps (duty and standby) and one jockey pump for automatic pressure maintenance and reliable fire protection.
One pump operates as the primary fire pump, while the second serves as a standby unit to ensure uninterrupted operation if the duty pump is unavailable or under maintenance.
The jockey pump maintains system pressure by compensating for minor pressure losses, preventing unnecessary operation of the main fire pumps.
Yes. CHINHER offers customized pump models, capacities, controllers, voltages, frequencies, piping layouts, and base frames to meet different project requirements.
The EEJ system can be designed and manufactured according to customer specifications and applicable international fire protection standards, including NFPA requirements where requested.
| Model | Q (GPM) | H (Bar) | Electric Option 1(Monoblock) | Electric Option 2(End suction) | Diesel | Jockey Option 1 | Electric Option 3 (Split Case) |
| EDJ 50/6 | 50 | 6 | – | CSM 32-250/55 7.5HP | CSD 32-250/55 8.5HP | CDL(F) 1-15 1HP | – |
| EDJ 50/7 | 50 | 7 | – | CSM 32-250/75 10HP | CSD 32-250/75 10HP | CDL(F) 1-15 1HP | – |
| EDJ 50/8 | 50 | 8 | – | CSM 32-250/110 15HP | CSD 32-250/110 12HP | CDL(F) 1-15 1HP | – |
| EDJ 50/9 | 50 | 9 | – | CSM 32-250/150 20HP | CSD 32-250/150 17HP | CDL(F) 1-17 1.5HP | – |
| EDJ 100/6-7 | 100 | 6-7 | CST 32-250/75 10HP | CSM 32-250/75 10HP | CSD 32-250/75 10HP | CDL(F) 2-11 1.5HP | – |
| EDJ 100/8 | 100 | 8 | – | CSM 32-250/150 20HP | CSD 32-250/150 22HP | CDL(F) 2-13 2HP | – |
| EDJ 100/9 | 100 | 9 | – | CSM 40-250/185 25HP | CSD 40-250/185 27HP | CDL(F) 2-15 2HP | – |
| EDJ 120/7 | 120 | 7 | CST 32-250/75D 10HP | CSM 32-250/75H 10HP | CSD 32-250/75H 12HP | CDL(F) 2-13 2HP | – |
| EDJ 150/7 | 150 | 7 | CST 40-250/110 15HP | CSM 40-250/110 15HP | CSD 40-250/110 17HP | CDL(F) 4-10 3HP | – |
| EDJ 200/6 | 200 | 6 | CST 50-250/150 20HP | CSM 50-250/150 20HP | CSD 50-250/150 27HP | CDL(F) 4-10 3HP | – |
| EDJ 200/7 | 200 | 7 | CST 50-250/185 25HP | CSM 50-250/185 25HP | CSD 50-250/185 27HP | CDL(F) 4-10 3HP | – |
| EDJ 200/8 | 200 | 8 | CST 50-250/220 30HP | CSM 50-250/220 30HP | CSD 50-250/220 32HP | CDL(F) 4-12 3HP | – |
| EDJ 200/9 | 200 | 9 | – | CSM 50-250/300 40HP | CSD 50-250/300 38HP | CDL(F) 4-12 3HP | – |
| EDJ 200/10 | 200 | 10 | – | CSM 50-315/370 50HP | CSD 50-315/370 58HP | CDL(F) 4-14 4HP | – |
| EDJ 250/7 | 250 | 7 | CST 50-250/185 25HP | CSM 50-250/185 25HP | CSD 50-250/185 27HP | CDL(F) 4-12 3HP | – |
| EDJ 300/6 | 300 | 6 | CST 50-250/185 25HP | CSM 50-250/185 25HP | CSD 50-250/185 27HP | CDL(F) 8-6 3HP | – |
| EDJ 300/7 | 300 | 7 | CST 50-250/220 30HP | CSM 50-250/220 30HP | CSD 50-250/220 32HP | CDL(F) 8-8 4HP | – |
| EDJ 300/8 | 300 | 8 | – | CSM 50-250/300 40HP | CSD 50-250/300 38HP | CDL(F) 8-8 4HP | – |
| EDJ 300/9-10 | 300 | 9-10 | – | CSM 50-315/370 50HP | CSD 50-315/370 58HP | CDL(F) 8-12 5.5HP | – |
| EDJ 350/7 | 350 | 7 | CST 50-250/220 30HP | CSM 50-250/220 30HP | CSD 50-250/220 32HP | CDL(F) 8-8 4HP | – |
| EDJ 400/6 | 400 | 6 | CST 65-250/220 30HP | CSM 65-250/220 30HP | CSD 65-250/220 32HP | CDL(F) 8-8 4HP | – |
| EDJ 400/7 | 400 | 7 | CST 65-250/300 40HP | CSM 65-250/300 40HP | CSD 65-250/300 38HP | CDL(F) 8-8 4HP | – |
| EDJ 400/8 | 400 | 8 | CST 65-250/370 50HP | CSM 65-250/370 50HP | CSD 65-250/370 58HP | CDL(F) 8-10 5.5HP | – |
| EDJ 400/9 | 400 | 9 | CST 65-315/450 60HP | CSM 65-315/450 60HP | CSD 65-315/450 61HP | CDL(F) 8-12 5.5HP | – |
| EDJ 500/6-7 | 500 | 6-7 | CST 65-250/300 40HP | CSM 65-250/300 40HP | CSD 65-250/300 38HP | CDL(F) 12-8 7.5HP | CSCM 80-270 |
| EDJ 500/8 | 500 | 8 | CST 65-250/370 50HP | CSM 65-250/370 50HP | CSD 65-250/370 58HP | CDL(F) 12-8 7.5HP | CSCM 80-270 |
| EDJ 500/9 | 500 | 9 | CST 65-315/450 60HP | CSM 65-315/450 60HP | CSD 65-315/450 61HP | CDL(F) 12-9 7.5HP | CSCM 80-270 |
| EDJ 500/11 | 500 | 10-11 | CST 65-315/550 75HP | CSM 65-315/550 75HP | CSD 65-315/550 75HP | CDL(F) 12-12 10HP | CSCM 80-270 |
| EDJ 500/13 | 500 | 12-13 | CST 65-315/750 100HP | CSM 65-315/750 100HP | CSD 65-315/750 100HP | CDL(F) 12-14 15HP | CSCM 80-270 |
| EDJ 500/14 | 500 | 14 | CST 65-315/900 125HP | CSM 65-315/900 125HP | CSD 65-315/900 125HP | CDL(F) 12-14 15HP | – |
| EDJ 750/6-7 | 750 | 6-7 | CST 80-250/450 60HP | CSM 80-250/450 60HP | CSD 80-250/450 61HP | CDL(F) 16-8 10HP | CSCM 100-250 |
| EDJ 750/8 | 750 | 8 | CST 80-250/550 75HP | CSM 80-250/550 75HP | CSD 80-250/550 75HP | CDL(F) 16-8 10HP | CSCM 100-310 |
| EDJ 750/9-10 | 750 | 9 | – | CSM 80-315/750 100HP | CSD 80-315/750 100HP | CDL(F) 16-10 15HP | CSCM 100-310 |
| EDJ 750/11 | 750 | 10-11 | CST 80-315/750 100HP | CSM 80-315/750 100HP | CSD 80-315/750 100HP | CDL(F) 16-10 15HP | CSCM 100-310 |
| EDJ 750/13 | 750 | 12-13 | CST 80-315/900 125HP | CSM 80-315/900 125HP | CSD 80-315/900 125HP | CDL(F) 16-12 15HP | – |
| EDJ 750/14 | 750 | 14 | – | CSM 80-315/1100 150HP | CSD 80-315/1100 150HP | CDL(F) 16-14 20HP | – |
| EDJ 1000/8 | 1000 | 8 | CST 100-250/750 100HP | CSM 100-250/750 100HP | CSD 100-250/750 100HP | CDL(F) 20-8 15HP | CSCM 100-310 |
| EDJ 1000/9 | 1000 | 9 | CST 100-250/900 125HP | CSM 100-250/900 125HP | CSD 100-250/900 125HP | CDL(F) 20-10 15HP | CSCM 100-310 |
| EDJ 1000/11 | 1000 | 10-11 | CST 100-315/1100 150HP | CSM 100-315/1100 150HP | CSD 100-315/1100 150HP | CDL(F) 20-10 15HP | CSCM 100-310 |
| EDJ 1000/12 | 1000 | 12 | CST 100-315/1320 180HP | CSM 100-315/1320 180HP | CSD 100-315/1320 170HP | CDL(F) 20-14 20HP | – |
| EDJ 1000/14 | 1000 | 13-14 | CST 100-315/1600 220HP | CSM 100-315/1600 220HP | CSD 100-315/1600 225HP | CDL(F) 20-14 20HP | – |
| EDJ 1250/8 | 1250 | 8 | – | CSM 125-250/1100 150HP | CSD 125-250/1100 150HP | CDL(F) 32-60 15HP | CSCM 125-230 |
| EDJ 1250/9 | 1250 | 9 | – | CSM 125-315/1320 180HP | CSD 125-315/1320 170HP | CDL(F) 32-60 15HP | CSCM 125-290 |
| EDJ 1250/11 | 1250 | 10-11 | – | CSM 125-315/1600 220HP | CSD 125-315/1600 225HP | CDL(F) 32-80 20HP | CSCM 125-290 |
| EDJ 1250/12 | 1250 | 12 | – | CSM 125-315/1850 250HP | CSD 125-315/1850 250HP | CDL(F) 32-80 20HP | – |
| EDJ 1250/13 | 1250 | 13 | – | CSM 125-315/2000 270HP | CSD 125-315/2000 270HP | CDL(F) 32-100 25HP | – |
| EDJ 1500/8 | 1500 | 8 | – | CSM 125-250H/1320 180HP | CSD 125-250H/1320 170HP | CDL(F) 32-80 20HP | CSCM 150-405 |
| EDJ 1500/9 | 1500 | 9 | – | CSM 125-315/1320 180HP | CSD 125-315/1320 170HP | CDL(F) 32-80 20HP | CSCM 150-405 |
| EDJ 1500/10 | 1500 | 10 | – | CSM 125-315/1600 220HP | CSD 125-315/1600 225HP | CDL(F) 32-80 20HP | CSCM 150-405 |
| EDJ 1500/12 | 1500 | 11-12 | – | CSM 125-315/1850 250HP | CSD 125-315/1850 250HP | CDL(F) 32-100 25HP | – |
| EDJ 1500/13 | 1500 | 13 | – | CSM 125-315/2000 270HP | CSD 125-315/2000 270HP | CDL(F) 32-100 25HP | – |
| EDJ 2000/8 | 2000 | 8 | – | CSM 150-250/1600 220HP | CSD 150-250/1600 225HP | CDL(F) 45-50 25HP | CSCM 200-520 |
| EDJ 2000/9 | 2000 | 9 | – | CSM 150-250/2000 270HP | CSD 150-250/2000 270HP | CDL(F) 45-50 25HP | CSCM 200-520 |
| EDJ 2000/10 | 2000 | 10 | – | CSM 150-315/2500 340HP | CSD 150-315/2500 340HP | CDL(F) 45-60 30HP | CSCM 200-520 |
| EDJ 2000/13 | 2000 | 11-13 | – | CSM 150-315/3150 430HP | CSD 150-315/3150 410HP | CDL(F) 45-70 40HP | – |
| EDJ 2500/8 | 2500 | 8 | – | CSM 150-250/1600 220HP | CSD 150-250/1600 225HP | CDL(F) 64-40 30HP | – |
| EDJ 2500/9 | 2500 | 9 | – | CSM 150-250/2000 270HP | CSD 150-250/2000 270HP | CDL(F) 64-50 40HP | CSCM 250-480 |
| EDJ 2500/10 | 2500 | 10 | – | CSM 150-315/2500 340HP | CSD 150-315/2500 340HP | CDL(F) 64-50 40HP | CSCM 250-480 |
| EDJ 2500/12 | 2500 | 11-12 | – | CSM 150-315/3150 430HP | CSD 150-315/3150 410HP | CDL(F) 64-60-2 40HP | CSCM 250-480 |
| Item | Specification |
|---|---|
| Product | EEJ Electric Fire Fighting System |
| Main Pumps | 2 × Electric Fire Pumps |
| Jockey Pump | 1 × Vertical Multistage Pump |
| Pump Type | Split Case / End Suction / Vertical Turbine |
| Flow Rate | Up to 2000 m³/h |
| Head | Up to 250 m |
| Frequency | 50Hz / 60Hz |
| Voltage | Customized |
| Installation | Skid Mounted |
| Controller | Dual Electric Controllers + Jockey Controller |
Please leave the model you are interested in and we will contact you within 24 hours